Submersible pump cable sizing chart Use only stranded copper wire to pump/motor and ground. 6 Cable sizing 14 6. motor size Selec 2. 5 HP pump made by Franklin. 5 4: Sterling Pumps Pty Ltd T: 03 5941 3400 sales@sterlingpumps Jun 24, 2024 · By following this guide, you can confidently select and size submersible pump cables for your specific application needs, offering efficient and trouble-free operation of submersible pump systems. Start-up 16 8. The cables are waterproof, are meant to operate underwater for a prolonged time, and can withstand physical pressure very well. For each pump size, it lists the motor type and power ratings, cable sizes, dimensions, weights, and flow rate discharge capacities in m3/hr. Submersible Pump Cable Selection. Worst & Co. Whether you need to spec an entire system or replace a single part, FE Select puts convenience, product availability, and order management at your fingertips. This document provides specifications for various 3-inch, 4-inch, and larger borewell submersible pumpsets. For wiring only between equipment located at water wellheads and motors of submersible pumps installed in deep wells Sizing and selecting the right pump and motor is crucial in any submersible pump installation. : E233961 • 10' long electric cord comes with this submersible deep well pump. 8 245 1330 952 0. 2 Impurities in the water 10 12. Operation 16 8. Ideally, a cable that feeds a submersible borehole pump must: be sized to deliver adequate voltage to the motor work without overheating or burnout – both in the well/water and aboveground in air/conduct From the drop wire selection table, #6 can be use for up to 750 feet and #10 for up to 300 feet, (375 ÷ 750) + (200 ÷ 300) = 1. 167 which is greater than 1, so #10 can’t be used; #8 wire can be used for up to 470 feet. 37KW 220V Pump, then according to the 220V Cable Selection Chart below you will be able to use 1. In addition, they are also resistant to abrasion, oil, weather, and chemical impact, making them work in hostile industrial It is specifically designed and dedicated to be used as a submersible pump drop cable. from the Franklin manual, service factor amps for a 2 hp 230v 1 phase submersible motor are 13. It is 60M from the well to the electrical panel. 5mm² cable or higher. Example: 115 volt nameplate should have a Borehole Pump Power Cable Sizes No GB8627 Maximum cable length* ( metre ) at 240/1/50 single-phase or 415/3/50 three-phase supply. May 7, 2024 · Submersible Pump Cable Size Calculator Distance from Pump to Power Supply (in meters): Power of the Pump (in HP): Calculate Did you know that selecting the correct cable size for submersible pump systems in India can have a significant impact on their efficient operation and safety? It's not just about connecting the dots; it's about connecting the right dots. 5mm² 4mm² 6mm² 10mm² 16mm² 25mm² 35mm² 50mm² 70mm² 95mm² 120mm² 150mm² 185mm² 240mm² 4” 0. 246 230 365 546 924 1471 2338 3721 4691 5914 7457 8811 2011 FRANKLIN ELECTRIC AIM MANUAL SUBMERSIBLE MOTORS APPLICATION | INSTALLATION | MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors AIM MANUAL 2015 EDITION franklinwater. Louis, MO 63123 USA. 7 KW Continuous Duty KVA Code: F GS Pump Series Voltage 1 = 115 V 2 = 230 V 3 = 380 V 4 = 460 V 7 = 575 V Phase 1 = 1 Phase 3 Wire 2 = 1 Phase 2 Wire 3 = 3 Phase 3 Wire 4 = 4" Motor 5, 7, 10, 13, 18, 25 C= CentriPro Motor CL = w/CentriPro Motor, less Control Box RCL = Reduced Stage / CentriPro Motor less Control Box “GS” SERIES MATERIALS OF CONSTRUCTION Flow Horse- Best The chart below shows the naming for a Submersible Motor Control, standard box, capacitor run, 5 HP, 230 volt single phase drive. For reliable submersible pump cables and submersible pump wires, consider CKW as your trusted supplier. 21 0. Size Guidelines for Submersible Pump Cables. Fitting the cable plug to the motor 7 8. For other voltages, the cable size is to be selected for the length which is calculated as follows. 250+ feet Call pump hotline: 1-888-956-0000 area of the individual wire of a submersible drop cable 1. Wire Size Chart - Single Phase Wire Size Chart - Three Phase Motor Rating Cicuit Size Fuse Size Full Load Amps Copper Wire Size Volts HP KW 12 10 8 6 4 2 0 00 000 0000 250 300 350 400 500 600 120 (1ø) 1/4 20 10 5. We buy cable in bulk and cut to length to suit your requirements. 451 13. 292. The question is: What size cable is required in the well with a 1 HP, 230 Volt, 1 PH, 3W motor setting at 310 feet? 1. Mar 18, 2021 · Next, shut off the power to your pump and pull up the reference charts from Table 13 of the Franklin AIM Manual (also shown at the bottom of this blog) Now, locate the power cable to the submersible well pump, it should have 4 colored wires: Red, Yellow, Black and Green. 75 45 70 110 180 0. TABLE 15 Three and Six Wire Cable, 50 Hz Service Entrance to Motor – Maximum Length in Metres 90°C Motor Rating Metric Cable Size, Square Millimeters, Copper Wire - 90°C Rated Insulation Volts kW HP 2. Specs Listed Below CentriPro Pump Control Box Model: CB50412CR HP 5, Volts 230 Control Box Specs: 5 HP 230 Volt 24 Amp 3450 RPM 27. 5: 7. 554 0. 5mm² cable up to 120m. com MaximumSubmersiblePowerCableLength Cablelengthinfeet–startertomotor Aug 3, 2020 · Carry Pumps, Inc. 7 1. Q2: How do I calculate voltage drop for a 1HP pump 500 feet away? Use the formula above or an online submersible cable size chart. This is a 3 wire pump with ground (3 wires + ground wire) • This pump uses high quality UL approved motor, UL file No. 5 91 152 243 6. From this, it is easy to deduct the challenges in selecting/sizing the right cable. Required total length of cable (D + E + F) 3. 1 Installation depth 9 11. household. 314-631-9200 1 = 1 Phase 3 Wire 2 = 1 Phase 2 Wire 3 = 3 Phase 3 Wire 4 = 4" Motor 5, 7, 10, 13, 18, 25 C= CentriPro Motor CL = w/CentriPro Motor, less Control Box RCL = Reduced Stage / CentriPro Motor less Control Box “CS” SERIES MATERIALS OF CONSTRUCTION WATER END DATA NOMENCLATURE 3. The size of the cable to be selected for 107m, from the cart is Service Wire part #: PT10/3GG 0. In a replacement installation, the well already has 210 feet of buried #12 cable between the service entrance and the well head. 5 4 x 4 4 x 6 4 x 10 4 x 16 maximum cable length in metres 0. Table 11 gives the maximum length of wire to stay under a 5% voltage drop. Cable sizes and lengths are maximum allowable. 780 0. 5 10 100 160 250 410 650 990 9. When the pump turns The chart below displays information for motor wire size, breaker size, thermal overload ratings, and other data for three-phase AC motor circuit protection. F. If the total length of cable required exceeds 120m you must then take 2. 75" 3. Apr 8, 2020 · Submersible pump cable sizing tables list the maximum number of feet of each sizing cable you can run from the service entrance to the motor for each horsepower motor. ) 0. 2 Selection of diaphragm tank and setting of precharge pressure and pressure switch 16 8. Application: It's not just a generic pump curve calculator, this tool takes your application data and comes up with the most suitable model among all available options within the WEDA range. 55 0. t SQ pump incl. Based on 3-Wire Induction Run requirements; Capacitor Run requirements may vary. Do you still wonder how to select the right submersible pump? Drainage, sludge or slurry. Do NOT use motor in swimming areas. Install wire and ground according to the National Electrical Code (NEC), or the Canadian Electrical Code, as well as all local, state and provincial Order 4 wire submersible pump cable by the foot online at R. com c wtwzGhtjkvuhskjvt c htjkvuhskjvt 3210-636 2/21 7. Fault finding chart 18 10 . 22 Submersible Discharge Head Well Casting Diameter Inch 6 8 10 12 14 16 18 20 A 280mm 343mm 406mm 483mm 533mm 597mm 635mm 698mm wire pump with ground (2 wires + ground wire) • MA0419X-12A-E and SS. SQ pump incl. Domestic Pumps - Selection chart2024 1 75 mm (3”) Borewell Submersible Pumpsets : CORA 75-20C + UMAI (S) 75 75 mm (3”) Borewell Submersible Pumpsets : CORA 75-25C + UMAI (S) 75 75 mm (3”) Borewell Submersible Pumpsets : CORA 75-30C+UMAI (S) 75 Motor type Motor rating Pump type & Stage Cable size Rated Current Discharge UMAI (S) 75 kW HP Jun 22, 2014 · What size wire and breaker is needed for a 5hp Submersible Pump. They are suitable for applications requiring a flow up to 450 m3/h and a head up to 425 Oct 3, 2019 · Code for each wire and cable category is identified in Tables 1, 2, and 3 of this Marking Guide. For deeper wells, choose a round submersible pump cable to prevent kinking and abrasion. 1 Phase, 3- or 2- Wire Cable, 60 Hz. 744 6. PVC 3 CORE FLAT CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS) No. This chart also indicates the wire gauge (AWG) of the wire to use to power a pump, which depends on the amperage draw of the pump and the vertical distance the pump lifts the water. 1 Contaminated pumps 17 10. PHILFLEX Submersible Pump Cable meets and exceeds UL 83 Standard and ICEA S-95-658 standard. 0 138 130 126 105 95 80 56 Submersible Pump Cable, Flat Black THW/PVC | Stranded copper conductors are insulated with color coded PVC (type THW or RHW-2) and configured flat and parallel with green insulated ground and overall PVC jacket applied directly over the conductors with a non-penetrating web. Cables #1 and #2 have voltage drop of 26 volts/1,000 ft and 20 volt/1000 ft @ 25 Use only copper wire when making connections to pump and control box. Manuals Form 2207 Registro de instalación (Español) Type: PDF Size: 0. 5 180 0. CUT TO LENGTH 12-2/14-2 FLAT YELLOW SUBMERSIBLE PUMP CABLE WIRE 600V COPPER For example if you are using a 0. com · 800 - 492 - 2779 · controls@carrypumps. 90" Effective diameter with cable guard MOTOR W. OTHER MAIN APPLICATIONS FOR DLO CABLES ARE: • Railroad and mass transit car wiring • General building wire RHH/RHW-2 as per UL 44 • Deep well submersible pump cable Type HTF3 Flat Electrical Submersible Pump Cable. 75 1 35 50 85 140 210 1. Maximum lengths shown maintain motor voltage at 95% of service entrance voltage, running at maximum nameplate amperes. It lists the pump type, phase, horsepower, stages, head range, discharge rate, and delivery size for over 60 different pump models. Atlas Copco's new pump sizing calculator will find the pump you need in a few Use only stranded copper wire to pump/motor and ground. The pump is set at a depth of 55 m, the total cable length from the junction to the control panel is 76 m and the 4. 7 Fitting the submersible drop cable 14 6. The correct cable size is determined by various factors, including current rating, insulation requirements, and load specifications. 5 HP pumps. 10" DP 160. 92 MB. We will conclude the topic in the January 2024 issue with defining voltage CABLE SIZES FOR SUBMERSIBLE MOTORS SINGLE PHASE 230V-50Hz cable section in mm2 kW HP 4 x 1 4 x 1. These ESP cables offer an efficient, rugged and easy to handle solution that delivers reliable The document appears to be a selection chart and specifications for submersible motor pumpsets made by KSB. 10" DP 215. com Calculate the correct well pump wire size with our Well Pump Wire Size Calculator. n Control Box: Required for all single phase motors. 11 Motor Flat Lead Cable (450°F) This #12 AWG 4-wire submersible cable features solid or stranded copper conductors. 3 12. Company USA: (937) 778-8947 • Canada: (905) 457-6223 • International: (937) 615-3598 5 INTRO www. Cable Chart Selection 220 Volt Cable Selection Cable Use the relevant table below to select the correct cable size. Referring to the 10mm² cable size on the table, 230m x 37% = 85m. Piping 8 10. The importance of this choice cannot be overstated, as the wrong cable No. Choose LADA for reliability and savings on your water management needs. HP . Damage to the electrical cables can cause shock, burns or death. 75 1. Horner Jr. To avoid over-heating wire and excessive voltage drop at motor, be sure that wire size is at least as large as size listed in cable sizing charts for your horsepower pump and length of wire run. 9 Type HTF3 Flat with Capillary Tube Electrical Submersible Pump Cable. 75 5. 90 – 250 feet Deep well submersible pump. To determine the size of the well pump you need, it is essential to consider your specific water demand requirements. Maintenance and service 17 9. RoHS APPLICATIONS For use with submersible pumps and irrigation equipment. 2 3 30 50 75 125 200 Three-phase 230 V - 50 Hz Wire/Control Blank = 2 wire C = Optional Control Phase (PH) Blank = 1PH 3 = 3PH EXAMPLE of pump Model Number configuration: WT Series Stainless Steel Fitted Submersible Pump End HP Range: . Fitting the cable guard 8 9. Cable selection chart is based on horsepower, voltage, and length of cable required. 5 HP 2 HP 3 HP 5 HP Pump Wire Configuration 2 Wire 3 Wire Phase 1 ∅ 3 ∅ Site Voltage 115V 230V Clear filter Cross reference the distance from your pump to the electrical service entrance to determine the correct gauge. What size cable should be used for this? And what size circuit breaker? I would like to use NYY underground. Water demands vary from just a few gallons per minute to hundreds of gallons per minute. Franklin Wire Sizing Chart: Four Wire Splice Kit Wire Size #8 Ground SP8C-4. 27 MB. Distance from pump to the power source (outside 44 m (D + F an Electrical Submersible Pump (ESP) system depends on the performance and reliability of the power feed through to the wellhead, power cable, motor lead cable, pig tail connectors and related equipment such as the pump and motor. 41 4. 75hp, 230v 2. com ALL ELECTRICAL WORK A bound pump will cause locked rotor amps performance chart of 100 mm (4") water filled submersible pump an series at 50hz frequency , 200 VOLTS RATED VOLTAGE FOR SINGLE PHASE & 415 VOLTS RATED VOLTAGE FOR THREE PHASE 1 KS4HH - 1020 0. (2) For Star Delta Starting reduce current by 1/3 for selecting suitable cable . Distance from pump to the power source (outside 44 m (D + F) + inside 6 m (E)) 50 m 3. 75 HP 1 HP 1. com Page1 CONSTRUCTION OF THE CABLE CONDUCTORS It is the current carrying component of the cable. The pumps are suitable for water Submersible Motors Application • Installation • Maintenance Manual Contents The submersible motor is a reliable, efficient and trouble- free means of powering a pump. Cables 108 Cable sizing charts 109 11. For items not in stock at the time of order, the displayed price may not reflect final cost. In this module, we will show you how to optimise your cable-sizing process. Switch the T6-600 to the “A” setting and then slide the yellow forks 75 mm Borewell Submersible Pumpset : CORA 75-20C + UMAI (S) 75 75 mm Borewell Submersible Pumpset : CORA 75-25C + UMAI (S) 75 75 mm Borewell Submersible Pumpset : CORA 75-30C+UMAI (S) 75 Motor type Motor rating Pump type & Stage Cable size Rated Current Discharge UMAI (S) 75 kW HP CORA 75-20C mm2 Amp (m3/hr. 5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 4 5. goulds. What does all this mean? Simply it’s the best cable for your requirement. BenefitsExplanationEfficient Pump SelectionAccurately calculate the required flow rate and TDH to select the right pump size. DP10 Performance Curves & Selection Chart. 5 – 10 ½ – 3 7 1¼ 4" CCW 10GS 3 – 16 ½ – 5 10 1¼ 4" CCW 13GS 4 – 20 ½ – 3 13 1¼ 4" CCW 18GS 6 – 28 ¾ – 5 18 1¼ 4" CCW 25GS 8 – 33 1 – 5 25 1¼ 4" CCW ① Rotation is counterclockwise when observed from pump discharge end. 10 AWG (6mm2) for copper, go to • Meets NEC® code for submersible pump grounding requirements • UL Standard 83 • UL Type THW Conductors FEATURES & OPTIONS: • Sequential footage marking on flat jacketed and parallel cables DESCRIPTION SIZE AWG & # OF CONDUCTORS STRANDS Insulation Nom Thickness (inch) Cable Nom Dimensions (Inch) APPROX. Table 3: Cost Calculations of Cable size Cable size Capital investment ($) AWG# 1 AWG #2 AWG #4 48,872 42,886 35,711 Monthly Cost of Total Total Power payback power monthly Resistance loss period loss cost (Ohm/1000ft) (KW) ($/month) ($/month) ($/month) 1085 0. Feb 13, 2007 · CAUTION -- Use of wire size smaller than listed will void warranty. Distance from pump to the power source (outside 44 m (D + F SUBMERSIBLE PUMP CABLE AND POWER CABLE SELECTION Check cable size against Submersible Wire Size Chart A. 5 140 220 340 560 880 7. Submersible power cable must be UL listed or CSA Certified for submersible pump applications. Full technical support available. 220V CABLE SELECTION CHART (Cable Cable Selection Guide for submersible motors, 3 wire, 415V, 2 pole, 3 phase, 50 Hz kW. Improper sizing will result in excessive voltage drop and consequently im-paired pump performance and efficiency. 8 2. • HP range from 1/2 to 1 1/2 • Max. 5 3. Full-Load Current and Circuit Protection Data for Three-Phase AC Motors Application - Three-Phase Motors. Atlas Copco's new pump sizing calculator will find the pump you need in a few SUBMERSIBLE PUMP CABLES FLAT BLACK THW/PVC 600 Volt Copper, Heavy Duty $:*± $:* Description: Stranded copper conductors, insulated with color coded PVC (type THW), configured flat and parallel with green insulated ground, and overall PVC jacket applied directly over the conductors with a non-penetrating web. Taking into consideration horsepower, voltage, phase, and distance this chart will point you to the Cable Selection Chart for Submersible Pumps, Manufacturer of Submersible Pumps, Borehole Pumps, Pond Pumps, Water Pumps, Centrifugal Pump, V3 Submersible Pumps, V4 Submersible Pumps, Sewage Pumps, Turbine Pumps, Submersible Pumps, V6 Submersible Pumps, V8 Submersible Pumps, in Gujarat, India. carrypumps. Distance from pump to the power source (outside 44 m (D + F Do not lift, carry or hang pump by the electrical cables. 5 HP Star - Delta - Double Cable 10 HP and above. 0 1. Jul 23, 2021 · A Comprehensive Guide To Submersible Pump Wire The goal of submersible pump cables is to supply power to submersible underwater pumps. For example if you are using a 0. Nov 15, 2023 · Part 2. 5 1. Thus 130m x 37% = 48m - not sufficient for the borehole. 5 ½ – 2 5 1¼ 4" CCW 7GS 1. Use the cable calculator to add your installation details for sizing guidance and cable type suggestions. Refer to table Intelligent Protection Boxes (Full protection Box) Variable Speed Drives (VSD’s) MP-S1 - Overload protection - Pump stalled protection - Dry run protection with sensor - Under voltage protection - Over-voltage protection - Changing speed of pump for Cables 99 Cable sizing chart 100 10. Taking into consideration horsepower, voltage, phase, and distance this chart will point you to the ITT Goulds Pumps Technical Data Water Products Goulds Pumps is a brand of ITT Corporation. Mar 1, 2012 · This article helps pump installers decide which type and size of pump cable to use. Refer to Section 8, Tables 1 & 2 for selection chart. 5 4 6 10 16 25 35 50 70 95 120 150 185 240; 380Volt 415 Volt 50Hz: 5. Cable sizing 7 6. Distance from pump to the power source (outside 144 ft (D + F) + inside Cable Selection Chart for Submersible Pumps, Manufacturer of Submersible Pumps, Borehole Pumps, Pond Pumps, Water Pumps, Centrifugal Pump, V3 Submersible Pumps, V4 Submersible Pumps, Sewage Pumps, Turbine Pumps, Submersible Pumps, V6 Submersible Pumps, V8 Submersible Pumps, in Gujarat, India. DIRECTION ROTATION - THREE PHASE ONLY All McDonald submersible pumps rotate in a counter-clockwise direction This is a Lift/Amps/Flow Chart for the Flojet pump heads used in the Nemo 12 Volt and the Nemo 24 Volt Submersible Pumps. 6 1. Taking into consideration horsepower, voltage, phase, and distance this chart will point you to the With a legacy of over 40 years, LADA offers a wide range of pumps, expert craftsmanship, and prompt after-sales service. Let us assume you need to find the correct cable for a submersible pump equipped with a 18,5 kW, 400V/50Hz direct on-line rated motor used for drinking water supply to a community water system. Thus 10mm² submersible pump cable must be used in the borehole. · Caro, MI 48723 www. For 3-wire plus ground models, motor and control box voltage must match. To reduce the risk of electrical shock, disconnect power supply before working on, or around the water system. Pump Sizing Pump sizing - or fill out our questionaire and we'll do it for you! Sizing Forms Use these pump sizing forms and pump sizing charts to make proper pump selection: Wire Sizing choosing correct submersible pump cable is very important. Optimal PerformanceAvoid oversizing or undersizing, achieving optimal pump performance. . PVC 3 CORE FLAT CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS) General purpose UL 83 listed Type THW Deep Well Submersible Pump Cable features solid or stranded copper conductors individually insulated with a tough Type THW polyvinyl chloride (PVC) compound. By Ed Butts, PE, CPI We kicked off a three-part series last month on defining the basics of electrical cable and conductor selection. 10" DP 125. An ISO 9001:2015 Certified Company Booster Pumps | Borehole Pumps | Centrifugal Pumps | Control Equipment | Diaphragm Pumps | DIY Borehole Kits | End Suction Pumps | End suction range | Fountain pump | Fountain Pumps | Hot Water Circulation Pump | Pond Pumps | Pressure Pumps | Quality Pool Pump Spares | Solar Borehole Pumps | Solar Inverters DC-AC | Submersible Pumps | Swimming Pool Pumps | Variable Speed Drive Feb 4, 2022 · Submersible Pump Cable Suppliers | (ESP) Electric Sub/Sump-Pump Wire, Cables, and Cord Manufacturers Specifications Sizing, Selection Chart, and References | Price/Pricing, Cost per foot to buy Deep Well Rubber/Plastic Flat/Round Copper or Aluminum conductor, Armored or Non-Armored for deep-well pumps. motor size SQ 2-70, motor size 1,15 kW 2. The balance of 37% is left for the borehole. Selected cross Motor Adapter (see Water End Data chart) • 10 HP and Larger Water Ends Have 6” Motor Adapters n Motor: • 4" motor required for 3 HP and 5 HP pumps. For the 2 hp motor #14 wire is good for up to 150 ft, service entrance to motor. • 6" motor required for 10 HP and larger pumps. PID- 10- 02 SMC - CR 50 2 1 - 02 Introduction SECTION PAGE DATE A Crane Co. The conductor suitable for applications at temperature not exceeding 60C and voltage not exceeding 600 volts. Further product documentation 115 The Grundfos SP range of submersible pumps is UL Listed as Type THW-Deep Well Submersible Pump cable Rated 75 degrees C, 600 volts Conductor Material: Bare Copper Guage: 2-14; UL Listed as Type THW-Deep Well Submersible Pump Cable Rated 75 Degrees C, 600 Volts Resistant to Acid, Abrasion, Alkalis, Flame, Gas and Oil; Water and Sunlight Resistant; Cable is Sequentially Marked Oct 2, 2017 · The cable size is selected based on its current carrying capability. Energy EfficiencySelect the pump size that operates at its highest efficiency point, reducing energy consumption. www. (19 m) Required total length of cable (D + E + F) 3. For aluminum cable, go up two sizes from chart (for example, if the chart calls for No. Pump & Tank Selection 0 – 25 feet Shallow well or convertible jet pump, install in shallow (single pipe) con˜ guration. 17 hours ago · Q1: Can I use a flat submersible pump cable in a deep well? Flat cables are best for shallow applications (<100 ft). Search Amazon for your Electrical products such as wire, tools, extension cords, and accessories. St. You will also learn about the Grundfos cable-sizing tool and how it can benefit you in your work. · 1360 Prospect Ave. area of the individual wire of a submersible drop cable 1. Friction loss tables 113 12. Save TimeEliminate metal plumbing, and all other metal near the motor or motor cable, to the power supply ground terminal using wire no smaller than motor cable wires. mersible drop cable 1. Wire Size in mm2 All cable lengths meet NEC for jacketed 60°C copper cable. 5mm2 2. 1 Minimum flow rate 16 8. Sizes 1/0 AWG and larger are rated for cable tray applications with flame retardant features. 186 291 464 692 1171 1863 2350 3737 4715 5942 7492 1/3 20 10 7. 15 Service Factor 3. How to find the size of a cable? Cable size calculator to aid specification of cables to British Standard BS7671 and International standard IEC 60364-5-52. 2 1. It is totally flexible and smooth, class 5 standard. Installing the pump 9 10. 30 1. Conductor sizes #1 and #2 fall in this category. Using the motor amps (88) and the following cable voltage drop chart, select a cable size with a voltage drop of less than 30 volts per 1,000 ft. 25 – 90 feet Convertible jet pump, installed in deep (two pipe) con˜ guration or deep well submersible pump. Find the correct wire size for your pump. Jul 24, 2023 · This page on what size well pump do I need reveal more on all you need to know about choosing the right well pump size. Submersible pump cable. 910 8. When it comes to installing a well water pump and all the parts it’s composed of, there’s little room for mistakes. Motor Cable Size Sizes kW 1. • 1¼” NPT discharge Do I need to connect all three submersible pump wires u, v and w? (Labeled 1, 2, 3 on all 2018 pumps) This is not a 2 wire DC, 3 phase pump so it needs all 3 phases. Select SQ pump incl. com Engineered for life Residential Water Systems General purpose UL 83 listed Type THW Deep Well Submersible Pump Cable features solid or stranded copper conductors individually insulated with a tough Type THW polyvinyl chloride (PVC) compound. , Maximum 60°C. When it comes to selecting submersible pump cables, following size guidelines is essential to ensure optimal performance and safety. It's not just a generic pump curve calculator, this tool takes your application data and comes up with the most suitable model among all available options within the WEDA range. 37 120 200 325 440 723 Cable termination kit, type KM 30 Cable termination kit, types M0 to M6 30 Submersible drop cable 31 Pt100 32 Cable Sizing Drop cables 33 Sizing of cable 40 Order data 3 x 220 V, 60 Hz 41 3 x 220-230 V, 50 Hz 42 3 x 380-415 V, 50 Hz and 3 x 460 V, 60 Hz 43 3 x 380-415 V, 50 Hz and 3 x 460 V, 60 Hz 44 3 x 500 V, 50 Hz and 3 x 575 V, 60 Hz 45 3 • Flow up to 36 GPM • Head up to 780 ft. Due to tariffs, prices may fluctuate. 5mm2 4mm2 6mm2 10mm2 16mm2 (kw) (hp) (a) (mm2) maximum lengths for submersible borehole cable (m) 0. Higher operating efficiency will be obtained by using the next larger cable size when lengths approach listed limits. Atlas Copco's new pump sizing calculator will find the pump you need in a few (4” Stainless Steel Submersible Well Pumps) Curves & Quick Select Charts 5 GPM: 28: 7 GPM: 30: 10 GPM: 32: 13 GPM: 34: Wire Sizing: 57: 4: Do not lift, carry or hang pump by the electrical cables. motor size 2. • 4" or 6" motors can be used for 7. com aymcdonald. 5 25 35 60 95 145 240 1. Submersible Well Pumps; Submersible & Vertical Lineshaft Turbines; PDF Size: 41. Cable is selected for the maximum pump setting plus the offset distance Well Size Rotation① 5GS 1. 95 3. The pump usually refers to both the pump itself and an electric motor, which together make up the pumping unit. 2 0. 5 190 300 460 750 5. There are two classifications of insulated multi-conductor cable used in submersible pump applications: submersible pump cable and underground feed cable, commonly known as UF. 0 3. WEIGHT (Lb/Mft) Jun 21, 2019 · Some water wells can be very deep at over 800’ or more while others are shallow at 50’ or even less. Sizing and selecting the right pump and motor is crucial in any submersible pump installation. 5 S. 5 7. Starting the pump for the first time 10 12. 75 / 1. E. It provides information on borewell submersible pumps in various sizes ranging from 75mm to 200mm bore diameters. This table is based on copper wire. Submersible power cable must be UL listed for submersible pump applications. Amp 1 Phase 60 Hertz 1. The pumps can operate on single phase 220 volts or 3 phase 380 volts power at 50 Hz and are designed for use in borewell water extraction applications. 5 - 200 HP, 60 Hz Capacities From the drop wire selection table, #6 can be use for up to 750 feet and #10 for up to 300 feet, (375 ÷ 750) + (200 ÷ 300) = 1. 3 299 1251 793 1. Generator operation 9 12. 5mm² 2. In this overview we are going to explore the factors affecting the selection of the correct submersible well (8” Stainless Steel Submersible Well Pumps) General Material Data 38 550 GPM 39 650 GPM 40 800 GPM 41 Weights & Dimensions 550 GPM 42 650 GPM 43 800 GPM 44 Wilo-SPI 10 (10” Stainless Steel Submersible Well Pumps) General Material Data 45 Curves 1200 GPM 46 Weights & Dimensions 1200 GPM 47 650 GPM 7”, 8”, 10” Motor Data 48 Wire Sizing Aug 27, 2024 · When installing a submersible water pump, one of the most critical decisions you'll make is selecting the right cable size. 4 3 lpm 10 20 30 40 50 Aug 6, 2015 · I have a very deep well 130M deep with a submersible 1. 386 * Number of wires is approximate and wire diameter is normal; they shall be such as to satisfy the requirements of conductor resistance as per class 5 of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360 . 8 0. 2 – 7. Friction loss tables 102 11. Totally submersible to 200 metres. 5 2 30 45 75 115 190 305 2. Wires should be color coded for ease of maintenance and troubleshooting. But it’s also important to size your cables correctly. 5: 2. com fax303-322-7242 sales@geotechenv. We stock lengths of wire from 50 feet to 1000 feet in 8, 10 and 12 gauge to centrifugal pumps, horizontal multi-stage and vertical multi-stage pumps. 10 Type HTR3 Round Electrical Submersible Pump Cable. 8417 New Hampshire Ave. Example : For a 20 HP motor at 350 volts & 90 meters actual cable length, calculated lenght = (415 / 350) X 90 = 107m. In order to Dec 17, 2017 · These wire sizing charts allow for voltage drop. Material Annealed flexible stranded class 5 to IEC/BS EN 60228 INSULATION 3. Submersible Pumps Submersible Well Pump Cable Selection Chart CABLE SELECTION CHART 2 or 3 Wire, 60 Hz, Single Phase Motor Maximum Cable Length in Feet (Motor to service entrance see footnotes 1 & 2) Motor Rating 60°C Insulation – AWG Copper Wire Size Volts HP 14 12 10 8 6 4 115 1/3 130 210 340 540 1/2 100 160 250 390 620 (1) Dol - Single Cable 1 HP - 7. MA0419X-12AEXT-230 have a control box. Price: REFERENCEPAGES 1-800-833-7958 www. All size and cable lengths shown are for copper wire only. Off Grid Submersible Pump Cable Sizing Chart Author: How to choose the right submersible pump cable for your off grid water system Subject: Theodore W. 1 1. 17 474 1267 It is obvious from PHIFLEX Submersible Pump Cable are primarily used for deep-well submersible water pump. per 1000 foot UL listed as Type THW-Twisted Submersible Pump cable Rated 75 degrees C, 600 volts Oil and grease resistant conductors For use within the well casing to supply power to the submersible pump unit This #12 AWG 4-wire submersible cable features solid or stranded copper conductors. DISCHARGE Cables 99 Cable sizing chart 100 10. The general rule is to never install a pump that has a greater capacity than your well. HOW TO USE THIS GUIDE The wire and cable types covered in this guide have been divided into three tables as follows: Table 1 — Building Wires and Cables, including some industrial cables Sizing and selecting the right pump and motor is crucial in any submersible pump installation. HP: 1. 37 0. 6/3 electrical wire is sold by the foot and can be cut to any length needed. 2 amps. The ground wire must be at least as large as the power supply wires. 5 2. Further product documentation 104 The Grundfos SP range of submersible pumps is table 6: borehole drop cable sizing cable dimension motor size cable full load current minimum size 1. Cable is selected for the maximum pump Apr 18, 2002 · 5. #12 wire is good for 250 ft. n Magnetic Starter: A magnetic starter Check cable size against Submersible Wire Size Chart on page 7. 5: 100: 165: 255: 390: 660: 1035: 1590: 2170: 3040 mersible drop cable 1. cranepumps. 5 80 140 210 340 Aqua Science offers PVC Submersible solid core twisted 2 and 3 wire with green ground wire for deep submersible pumps and double jacketed Direct Burial Type UF-B feeder wire. 5 121 202 0. 8 Pipework connection 15 7. Who we are Our buried cable uses 82mm + 130 = 63% of the allowable total. Max. 1. 5 - 15 HP, 60Hz Capacities to 100 GPM Heads to 1,360’ Pages 1-12 WS Series All Stainless Steel Submersible Pump End HP Range: . C. 1 7. Submersible pumps Features and benefits Pump range The SP-G pump range consists of pumps which can deliver a higher pressure or a higher flow compared to the rest of the SP pump range offered by Grundfos. 3 Minimum flow rate 10 Well Size Rotation① 5GS 1. dba High Lifter Pump Service Keywords: submersible pump,solar water pump,off grid, off grid water system Created Date: 1/23/2015 6:35:40 PM How to optimise cable sizing in submersible pumps (00:06:19) Take test: Test your knowledge About us. 50 60 90 140 0. Read the cross-sectional area of individual wire of the drop cable Example: 1. 48 outside diameter Ampacity NEC: 30 amps Raw Wire Weight: 180 lbs. The pump may be one of several types: shallow-well or deep - well, and jet, submersible or reciprocating. motor size 10 SQ07-200, 0. Founded in 1979, CKW is one of the leading Pump Sizing Pump sizing - or fill out our questionaire and we'll do it for you! Sizing Forms Use these pump sizing forms and pump sizing charts to make proper pump selection: Wire Sizing choosing correct submersible pump cable is very important. Local code requirements may vary. 2: c MH : 800. RUBBER FLEXIBLE CABLE- HO7RN-F ELECTRICWAY | Data Sheet - Armoured Cables SWA and AWA TEL +971-04-48170777 | FAX +971-04-8825700 | www. 1 Motor cooling and other considerations 10 12. Splicing the cable 7 7. Further product documentation 104 The Grundfos SP range of submersible pumps is Pump Selection with FE Select Input your specs or performance requirements, and our industry-leading tool, FE Select, will help you find the right Franklin Electric product for the job. 5 HP . acceptable liquid temp: 86°F (30°C) • Thread connections: NPT 1˝ to NPT 1 1/2˝ SUBMERSIBLE PUMP CABLE Solid or stranded bare copper condutors with PVC insulation 3 or 4 twisted conductors 600 Volts, -40°C. 2737 salesaymcdonald. 0 32 20 9. Selected Jan 7, 2025 · Follow the pump manufacturers’ suggestions over anything else because their own well pump amp draw chart and wire sizing usually account for everything: Code recommendations, distance, possible voltage drop, etc. Note : Table shows maximum allowable length of submersible cable for the given full load current where site voltage is normal ie 220 V. 1 Select the proper size cable. com Submersible Dewatering Pump other RHH/RHW rated conductors. 3 Built-in protection 17 9. /size of Wire Nominal diameter (mm) 12. NOTICE: See Pages 15 through 19 for typical wiring hookups and control box Mar 1, 1995 · How are voltage drop calculations used in sizing submersible pump power cables?What happens when the power source for a submersible pump is not located near the pump's control Motor Rating Cable Size Square Millimeters; Volts Kw HP 1. For Canadian installations, type RWU, TWU, SGOW or SWOW power supply cable is recommended. Voltage at the pump should be within 10% of name-plate rating. electricway. SP 270-G, SP 300-G and SP 360-G are semi-axial pumps. Thanks for any advice. 0 6. geotechenv. 5 4 x 2. In part two this month, we will continue the discussion with an emphasis on submersible pump cable. 19 1. cctkjwhherzreiahggqiaqwpnjtopowscsebjswgnvxwljg